Rosemount 0065/0185 Sensor Assembly - Emerson

August 2017 6 Quick Start Guide 2.2 Tubular thermowell sensor assembly Rosemount 248 Rosemount 644 Rosemount IP68 or IP65, connection heads Sensor with …

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Text of Rosemount 0065/0185 Sensor Assembly - Emerson

Quick Start Guide00825-0200-2654, Rev EADecember 2017Rosemount 0065/0185 Sensor AssemblyDecember 20172Quick Start GuideNOTICEThis guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe ( ) the Rosemount 0065 or 0185 Sensor was ordered assembled to a temperature transmitter, see the appropriate Quick Start Guide for information on configuration and hazardous locations could result in death or serious injury. Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and entries Unless marked, the conduit/cable entries in the transmitter housing use a 1/2 14 NPT thread form. Entries marked M20 are M20 x thread form. On devices with multiple conduit entries, all entries will have the same thread form. Only use plugs, adapters, glands, or conduit with a compatible thread form when closing these diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . 3Sensor assembly dimensions . . . . . . . . . . . . . . . 5Product certifications . . . . . . . . . . . . . . . . . . . . . 8Quick Start Guide3December diagramsFigure 1. Rosemount Series 65 RTD Lead Wire ConfigurationNoteFor 3-wire systems use one white and two red leads. Do not connect the white leads. Insulate or terminate the unused white lead in a manner that prevents shorting to the ground. For 2-wire systems, connect both sets of leads and spring-loaded adapter (termination codes 0, 1, or 3 only)Single elementDual elementTerminal block (termination code 2 and 4)Single elementDual elementRedWhiteWhiteRedRedRedGreenBlueBl ueBlack3416RedRedWhiteWhite6134123456456 123RedRedWhiteRedRedWhiteDecember 20174Quick Start GuideFigure 2. Rosemount Series 185 Thermocouple Lead Wire ConfigurationNoteTo distinguish the two sensors in Rosemount Dual 185 Sensors (flying lead or spring loaded styles), the lead wires of one sensor will be longer than the other terminal blockSingle elementDual elementTable 1. Rosemount Series 185 Thermocouple CharacteristicsTy p eAlloys (wire color)Sheath materialTe m p e ra t u r erange ( C)Limits of error interchangeability DIN EN 60584-2To l e r a n ce classJFe (+ black), Cu-Ni ( white) (321 SST) 40 to 375, 375 to C, t1KNi-Cr (+ green), Ni-Al ( white) (Alloy 600) 40 to 375, 375 to 10001NNi-Cr-Si (+ pink), Ni-Si ( white)1ENi-Cr (+violet), Cu-Ni ( white) (321 SST) 40 to 375, 375 to 8001TCu (+brown), Cu-Ni ( white) 40 to 125, 125 to C, t1311 (+)3(-)13464(+)6(-)1(+)3(-)Quick Start Guide5December assembly assembly without thermowellRosemount 248Rosemount 644Head or field mount transmittersRosemount IP68 or IP65 connection headsSensor with flying leads, terminal block, or spring-loaded adapter ExtensionsRosemount 644 with LCD display meterRosemount 314440 mm 25 mm L16 mm N N N LL N dimension measures from thread engagement mm 11 mm December 20176Quick Start thermowell sensor assemblyRosemount 248Rosemount 644Rosemount IP68 or IP65, connection headsSensor with flying leads or te r m i n a l b lo c kThreaded and flanged tubular thermowellsRosemount 644 with LCD display meter40 mmHead or field mount transmittersNUUN25 mmNAMURNAMUR For straight threading, N dimension references bottom of hex. For tapered threading, N dimension references thread engagement point (bottom of thread).UNUGBGN Quick Start Guide7December thermowell sensor assembly(1)1. The Rosemount 644 is available with or without a LCD with flying leads, te r m in a l b l o c k , o r spring-loaded adapterWeld-in, threaded or flanged barstock thermowellsRosemount 3144Stand-alone extensionsRosemount 248Rosemount 644Rosemount IP 68 or IP 65 connection headsRosemount 644 with LCD display meter40 mmHead or field mount transmitters11 mm L11 mm16 mm N 11 mm11 mm 60 mm UUU60 mmLL N dimension measures from thread engagement point. This dimension is 80 mm for Class 1500 and 2500 N 25 mmTU40 mmU60 mmDecember 20178Quick Start certificationsRev Directive informationA copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Location CertificationAs standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). AmericaThe US National Electrical Code (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective Locations CertificationsUSAE5 FM Explosionproof and Dust-Ignition proofCertificate: FM17US0170XStandards Used: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class 3810: 2005; ANSI/NEMA - 250: 1991Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G;T5( 50 C Ta +85 C); Type 4XCanadaE6 CSA Explosionproof and Dust-Ignition proofCertificate: 1063635Standards Used: CSA No. 0-M91, CSA No. 25-1966, CSA No. 30-M1986, CSA No. 94-M91; CSA No. 142-M1987, CSA No. 213-M1987 Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL i, Div 2, GP A, B, C, D; ( 50 C Ta +85 C)EuropeE1 ATEX Flameproof Certificate: FM12ATEX0065X Standards Used: EN 60079-0:2012 + A11:2013, EN60079-1:2014, Markings: II 2 G Ex db IIC Gb, T6( 50 C Ta +40 C), T1( 50 C Ta +60 C); 1180 Quick Start Guide9December 2017Specific Conditions of Use: certificate for ambient temperature non-metallic label may store an electrostatic charge and become a source of ignition in Group III the LCD cover against impact energies greater than 4 joints are not intended for suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N . shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor prove does not exceed 130 Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more AT E X I nt r i n s i c S afet yCertificate: Baseefa16ATEX0101XStandards: EN 60079-0:2012+A11:2013, EN 607960079-11:2012Markings: II 1 G Ex ia IIC T5/T6 Ga (see certificate for schedule) Specific Conditions of Use: equipment must be installed in an enclosure which affords it a degree of ingress protection of at least E X Ty p e n Certificate: BAS00ATEX3145Standards: EN 60079-0:2012, EN 60079-15:2010Markings: II 3 G Ex nA IIC T5 Gc ( 40 C Ta +70 C)NDAT E X D us tCertificate: FM12ATEX0065X Standards: EN 60079-0:2012+A11:2013; EN 60079-31: 2014Markings: II 2 D Ex tb IIIC T130 C Db ( 40 C Ta +70 C)Specific Conditions of Use: certificate for ambient temperature non-metallic label may store an electrostatic charge and become a source of ignition in Group III the LCD display cover against impact energies greater than 4 joints are not intended for suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N . shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more ; Pi = 500 mWT6 60 C Ta +70 CRTDs; Pi = 192 mWT6 60 C Ta +70 CRTDs; Pi = 290 mWT6 60 C Ta +60 CT5 60 C Ta +70 CDecember 201710Quick Start GuideInternationalE7IECEx FlameproofCertificate: IECEx FMG : IEC60079-0:2011, IEC60079-1:2014-06Markings: Ex db IIC Gb, T6(-50 C Ta +40 C), (-50 C Ta +60 C)Specific Conditions of Use: 1. See certificate for ambient temperature non-metallic label may store an electrostatic charge and become a source of ignition in Group III the LCD display cover against impact energies greater than 4 joints are not intended for suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N . shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more FlameproofCertificate: UL-BR Used: ABNT NBR IEC 60079-0: 2013; ABNT NBR IEC 60079-1: 2016; ABNT NBR IEC 60079-31: 2014Markings: Ex db IIC Gb : ( 50 C Ta +40 C), :( 50 C Ta +60 C) Ex tb IIIC T130 C Db ( 40 C Ta +70 C) Specific Conditions of product description for ambient temperature limits and process temperature non-metallic label may store an electrostatic charge and become a source of ignition in Group III the LCD display cover against impact energies greater than 4 the manufacturer if dimensional information on the flameproof joints is suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N . shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 Flameproof (0065 only)Certificate: TC17226Markings: IIC T6; ( 20 C Ta +65 C); Process Temperature: 20 C to +85 CSpecific Conditions of Use: wiring shall be suitable for a temperature over 80 Start Guide11December 2017EAC Belarus, Kazakhstan, RussiaEMTechnical Regulation Customs Union (EAC) FlameproofCertificate: RU : 1Ex d IIC Gb X Specific Conditions of Use: certificate for special Regulation Customs Union (EAC) Intrinsic SafetyCertificate: RU : 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X; 1Ex ia IIC T6 Gb XSpecific Conditions of Use: certificate for special Explosionproof/FlameproofCertificate: 13-KB4BO-0560XMarkings: Ex d IIC ; T6( 50 C Tamb +40 C), ( 50 C Tamb +60 C) Specific Conditions of Use: of E1, E5, and E6K1Combination of E1, I1, N1, and NDKMCombination of EM and IMDecember 201712Quick Start GuideFigure 3. Rosemount Temperature Sensor Declaration of ConformityEU Declaration of Conformity No: RMD 1059 Rev. N Page 1 of 2 We, Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 USAdeclare under our sole responsibility that the product, Rosemount Model 65, 68, 78, 85, 183, 185, and 1067 Temperature Sensors manufactured by, Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 USAto which this declaration relates, is in conformity with the provisions of the European Union Directives, including the latest amendments, as shown in the attached of conformity is based on the application of the harmonized standards and, when applicable or required, a European Union notified body certification, as shown in the attached schedule.(signature) Vice President of Global Quality (function) Chris LaPoint (name) 7-Sept-2017(date of issue) Quick Start Guide13December 2017cEU Declaration of Conformity No: RMD 1059 Rev. N Page 2 of 2 ATEX Directive (2014/34/EU) FM12ATEX0065X - Flameproof Certificate Equipment Group II Category 2 G (Ex db IIC Gb) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-1:2014 FM12ATEX0065X - Dust Certificate Equipment Group II Category 2 D (Ex tb IIIC T130 C Db) Harmonized Standards: EN60079-0:2012+A2013, EN60079-31:2014 BAS00ATEX3145 - Type n Certificate Equipment Group II Category 3 G (Ex nA IIC T5 Gc) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-15:2010 Baseefa16ATEX0101X - Intrinsic Safety Certificate Equipment Group II Category 1 G (Ex ia IIC T5/T6 Ga) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-11:2012 RoHS Directive (2011/65/EU)Harmonized Standard: EN 50581:2012 ATEX Notified Bodies FM Approvals [Notified Body Number: 1725] 1151 Boston Providence Turnpike Box 9102 Norwood, MA 02062 USA SGS Baseefa Limited [Notified Body Number: 1180] Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom ATEX Notified Body for Quality AssuranceSGS Baseefa Limited [Notified Body Number: 1180] Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom December 201714Quick Start Guide China RoHS Rosemount 0065/0185 List of Rosemount 0065/0185 Parts with China RoHS Concentration above MCVs Part Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr +6) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Electronics Assembly O O O O O O Housing Assembly O O O O O O Sensor Assembly O O O O O O SJ/T11364 This table is proposed in accordance with the provision of SJ/T11364. O: GB/T 26572 O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB/T 26572. X: GB/T 26572 X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. Quick Start Guide15December 2017December 201716Quick Start GuideQuick Start Guide17December 2017December 201718Quick Start GuideQuick Start Guide19December 2017Global HeadquartersEmerson Automation Solutions6021 Innovation , MN 55379, USA+1 800 999 9307 or +1 952 906 8888+1 952 949 7001 America Regional OfficeEmerson Automation Solutions8200 Market , MN 55317, USA+1 800 999 9307 or +1 952 906 8888+1 952 949 America Regional OfficeEmerson Automation Solutions1300 Concord Terrace, Suite 400Sunrise, FL 33323, USA +1 954 846 5030+1 954 846 Terms and Conditions of Sale can be found on the Te r m s and Conditions of Sale Emerson logo is a trademark and service mark of Emerson Electric and Rosemount logotype are trademarks of Electrical Code is a registered trademark of National Fire Protection Association, is a registered trademark and service mark of the National Electrical Manufacturers other marks are the property of their respective owners. 2017 Emerson. All rights Regional OfficeEmerson Automation SolutionsNeuhofstrasse 19a Box 1046CH 6340 BaarSwitzerland+41 (0) 41 768 6111+41 (0) 41 768 6300 Pacific Regional OfficeEmerson Automation Solutions1 Pandan CrescentSingapore 128461+65 6777 8211+65 6777 0947 East and Africa Regional OfficeEmerson Automation SolutionsEmerson FZE Box 17033Jebel Ali Free Zone - South 2Dubai, United Arab Emirates+971 4 8118100+971 4 Start Guide00825-0200-2654, Rev EADecember 2017*00825-0200-2654*

Related search results