EST3X Life Safety Control System - edwards-es.com

Page 3 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 1 R X 1 T X 1 R T S 1 C O M 1 A RS-485 BUS B RS-485 BU NETWORK OU A IN BB R X 1 T ...

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Text of EST3X Life Safety Control System - edwards-es.com

Page 1 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue EDWARDS Catalog u Mid-Sized Systems12-20-17LIFE SAFETY & INCIDENT MANAGEMENTEST3X Life Safety Control SystemDescriptionEST3X represents the latest generation of life safety control panels for mid to large sized applications. With large multi-message dis-plays and innovative controls, intuitive interfaces, and bold colored cabinets these systems capture the imagination, and catch the eye. But behind the LCD display is where they really microprocessors and chipsets take full advantage of the lat-est advances in computing technology, leading to smarter, faster, higher-capacity processing and more efficient designs. EST3X s patented Voltage Boost technology, for example, delivers consis-tent voltage even at low battery power resulting in lighter cable requirements and/or longer runs. That saves time and , advanced communications provide integrated IP com-munications via existing Ethernet networks directly to subscribed central stations. Email and text messaging options enrich this advanced communication environment with instant notification anywhere, any performance processing also leads to powerful networking features and versatile digital audio functionality. The wide range of EST3X configurations include standalone operation, networking with up to 64 nodes, or integration with an EST3 network com-prising as many as 64 nodes complete with mass notification capabilities and display of security sets a new standard in front-panel life safety control interfaces. Its exclusive SpeedTouch rotary control offers nimble forward and back scrolling through events and options, while a mere tap of the control selects items with a clean fluidity of motion. Its extra-large backlit display reveals up to eight concurrent mes-sages, and switch/LED strips provide ample space for meaningful custom labels. And for end users, large tactile control buttons instill confidence and promote quick response when time is of the Features Up to six intelligent analog loops hosting as many as 1,500 Signature Series devices per panel Optional integrated eight-channel digital audio 10 amp power supply with universal 94 to 264 Vac input voltage Patented Voltage Boost technology delivers consistent volt-age even at low battery power Four built-in 3-amp notification/auxiliary circuits Large 24-line by 40-character backlit LCD Simplified operation with the SpeedTouch rotary control 65 amp hour battery charger 64-node network nodes using copper and/or fiber Supports up to 30 R-Series remote annunciators Part of an end-to-end audio solution suitable for low frequency signaling in sleeping areas Space for up to three additional option cards such as extra SLC loops, amplifiers, or dialer/modem Optional Ethernet Interfaces for central station communication, email, and diagnostics 1,100 event history log Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor UL2572 Listed for Mass Notification, UL864 UUKL Listed for Smoke Control, UL864 Listed for releasing applications using SIGA-REL7165-1657: 0186/0306S3000COA 6087Page 2 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue ApplicationApplication flexibility is where EST3X s computing power is put to best use. This generation of control panels is equally at home as the center of a simple single-building standalone system as it is when part of a sophisticated life safety network serving thousands of points across multiple buildings. Optional voice evacuation bridges the gap left by other mid-range NetworkingNetworking is among EST3X s strong suits. Highly efficient RS485 connectivity, plus fiber-optic communications deliver faster re-sponse times and more sophisticated diagnostic capabilities, while cost-effective remote annunciation solutions keep basic monitor-ing and control always within simple EST3X network can comprise up to 64 nodes enough to serve the needs of most campuses and larger buildings. Its ability to join an EST3 network with as many as 64 nodes extends EST3X s reach into mass notification applications, security report-ing, as well as making it an ideal candidate for Capacity Audio An optional paging microphone provides local, as well as remote, audio features a full eight channels of integrated digital audio with up to two min-utes of on-board programmable message storage. An optional high quality paging microphone gives live access to local, as well as remote, audio functions. Auxiliary inputs are available for mass notification operations, and ZA Series amplifiers may be mounted directly on the EST3X rail Fidelity Audio Approved for Sleeping AreasEST3X is part of an end-to-end low frequency/high fidelity solu-tion listed to UL 464 and UL 864. Its audio system approved for code-compliant 520 Hz signaling in sleeping areas when used in conjunction with: a factory-supplied 520 Hz audio file one or more of the following amplifiers: 3-ZA20A, 3-ZA20B, 3-ZA40A, 3-ZA40B, 3-ZA95, SIGA-AA30, SIGA-AA50, 1B3-125, or 1B3-250 one or more Genesis High Fidelity speakersConsult the EST3X Compatibility List for IP and Cellular CommunicationsSeveral popular third-party IP/Cellular communicators have been tested with the EST3X control panel and are compatibility listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the EST3X control panel com-patibility documentation part number 3101801-EN for a full list of compatible System IntegrationEST3X borrows much from it s larger sibling, the venerable EST3 Life Safety Platform. And for good reason: by integrating with the EST3 networking and computing environment, an EST3X control panel can serve as a cost-effective remote node for extinguishing, smoke control, or even mass notification functions all within the same compliance and expansions benefit enormously from this arrange-ment, but programming and equipment management for new in-stallations is equally efficient as a result of these shared resources. EST3X will accommodate up to three EST3 modules on its own rail assembly, giving it access to such proven EST3 successes as zoned amplifiers, conventional device circuits, modem communi-cators, and RS-485 functions. Meanwhile, installers familiar with EST3 configuration will find that the two systems share many of the same programming and diagnostic and Remote Annunciation Up to 30 R-Series annunciators may be configured for each node on the EST3X to 30 R-Series LCD, LED annun-ciators and driver interface cards may be configured for each node on the EST3X network. No additional nodes are required for annunciation purposes. In addition, EST3X supports EST3 network annunciators, while GCI and GCIX driver interface cards provide cost-effective graphic annunciation solutions. And all annunciator inputs and outputs are easily programmable through the rules and labels function of EST3X s Software Definition to Count OnEDWARDS patented Voltage Boost technology delivers a con-sistent Vdc even at low battery power. This means lighter gauge cable can be used for equivalent distances compared with conventional power supplies, or longer wire runs on the same gauge cable. Either way, this breakthrough technology saves time and equipment costs, making EST3X not only a high-performance solution but a cost-effective one as s four on-board Notification Appliance Circuits are fully syn-chronized to UL 1971 standards without the need for external modules or other electronics. It s ample 10-amp power supply is finely tuned to get the most out of EDWARDS widely-acclaimed low profile Genesis notification backbox is designed for semiflush or surface mounting. Con-duit and nail knockouts, keyhole style mounting holes, and wide wiring troughs facilitate efficiency during installation. 7RS YLHZ%DFNER[%RWWRP YLHZ6LGH YLHZ6LGH YLHZ LQ FP Note: Add in ( cm). to height and width dimensions to allow for knockouts when framing in the backbox for semiflush 3 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue RX1TX1RTS1COM1ARS-485BUSBRS-485BUSNETWOR KOUTAAINBBRX1TX1RTS1COM1ARS-485BUSBRS-48 5BUSNETWORKOUTAAINBBRX1TX1RTS1COM1ARS-48 5BUSBRS-485BUSNETWORKOUTAAINBB3-ASU/3X-P MIPrimary Audio DataClass A or Class X3-ASU/3X-PMIPrimary Audio DataTo nextnetworknodeTo nextnetworknodeTo nextnetworknodeSFS1-CPU Main BoardSFS1-CPU Main BoardSFS1-CPU Main Board Network data circuit Network data circuit, Class A or Class X audio Network data circuit, Class B audioRequired for Class A or Class X onlyIf shielding is used, it must be continuous and free from earth wiring is power two-wire smoke detectorAuxiliary power, +24 VAuxiliary power, commonAPBBALOOP1SBBKRWMSHLOOP1LOOP124+1C AUXCAUX Signature (initiating) Data CircuitSFS1-CPU Main BoardWiringSystem LayoutUp to 30 Class B Annunciators. 4,000 ft. (3X-ETH)RS-232Relays: 3 Form CAux. Power: 24 VDC, A to three EST3 Local Rail Modules including: Signature Series Drivers Zoned Amplifiers Modem Communicators Network Short Haul Modems Fiber Optic Communications Interfaces Hardwired Initiating Device Modules Up to three Control/Display ModulesSLC1StandardSLC23-SDC13-SDDC1(occ upies one LRM expansion slot)Up to six intelligent analog loops hosting as many as 250 devices 3-amp Class B NACs. Four Class A NACs with , 3X-FIB83X-NET, 3X-FIBUL Listed SignalingUL Listed Life Safety DetectionUL Listed Life Safety DetectionUL Listed SignalingUL Listed SecurityUL Listed Mass NotificationSLC3SLC6SLC5SLC43-SDDC1(occu pies one LRM expansion slot)NAC 1NAC 4NAC 3NAC 2++++Wiring is supervised and power terminal marking indicates signal polarity when the circuit is active. Polarity reverses when the circuit is proper circuit supervision, break the wire run at each notification appliance and install the EOL resistor at the end of the not loop wires around notification appliance resistor Notification Appliance CircuitsPS10-4B Power supply++++FireWorksPage 4 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue CommonRelayOutputsSLC1 Signaling line circuitNetwork, annunciator, RS-232 circuitsSLC2 Signaling line circuitSFS1-CPU Main BoardChassis AssemblySFS1-CPU Main BoardPS10-4B Power supplySFS1-CPU Main Board The SFS1-CPU main board processes all infor-mation from modules installed within the cabinet as well as data received from other panels over the network data riser. When a network card is installed, the CPU employs a command set to determine its SpecificationsVoltage24 VDCCurrentStandby115 mA at 24 VDCAlarm115 mA at 24 VDCRelay outputsQuantity3 (alarm, supervisory, and trouble)UL typeCommonContact arrangementForm CRating30 VDC at 1 A resistiveAUX power outputsQuantity2Voltage24 VDC, resettable or A each circuit, A totalData network (RS-485)Nodes2 to 64 (requires optional network card)Performance classClass A, Class X, or Class BWire typeTwisted pair, 6 twists per foot, length5,000 ft. (1,524 m) between any three panelsCircuit resistance90 , F, Port (RS-232)The on-board serial port supports communication to the FireWorks graphical users interface or the FSB-PC series of protocols converters for ancillary communications to BMS length20 ft. (6 m) resistance13 , F, port (RS-485)Performance classClass B and Redundant Class BBaud rate9600 and 38400Wire typeTwisted pair, 6 twists per foot, length4,000 ft. (1,219 m)Circuit resistance90 , F, line circuitQuantity2 (second SLC requires optional 3-SDC1 card)Performance classClass A, Class X, or Class BCircuit capacity125 detectors, 125 single address modulesCircuit resistance100 , F, size18 to 12 AWG ( mm to mm )Ground fault impedance10 k Operating environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensingNotes For battery calculations, standby and alarm currents include all listed primary power supplies. The common trouble relay operation does not include AC trouble delay functionality and cannot be used for reporting troubles off premises per UL 864 10th edition. SFS1-CPU Main Board4X-LCD User InterfaceThe 3-SFS1 Electronics Chassis provides the mounting, internal power, and data distribution for the SFS1-CPU main board and up to three local rail modules. It installs over the PS10-4B Power cables connect the PS10-4B Power Supply to the back of the SFS1-CPU main SFS1-CPU main board mounts to the Electronics Component AssemblyEST3X systems are designed for quick assembly and easy access in the field. Components are modular and require no special tools to service or 4X-LCD as-sembly mounts to hinge pins on the CPU and connects with a single ribbon 5 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue PS10-4B Power Supply Card The PS10-4B Power Supply Card provides the required power and related supervision functions for the control panel, as well as filtered, regulated power to the rail chassis modules. It also provides 24 VDC for operating ancillary SpecificationsMains voltage94 to 264 VAC, 50/60 HzAC Input ampsBrownout level93 VRMSBattery charging capacity65 Ah Power Standby Current Alarm Current Supply RatingsVoltage 24vdc88mA 169mA Current 10 amps (UL), (ULC)Notification appliance/Auxiliary power circuitsUL ratingQuantity4Circuit configurationClass B1Output voltageSpecial: 24 Vdc Regulated: 24 VdcOutput currentSpecial: 3 amps Regulated: ampsEOLR15 k (UL P/N EOL-15, ULC P/N EOL-P1)WiringMains input 2Supervised, non power-limitedBattery inputSupervised, non power-limitedNAC outputsSupervised, power-limitedWire size18 to 12 AWG ( mm to mm )Ground fault impedance10 k Operating environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing1Class A when a CLA-PS10 Class A adapter card is installed. 2 Connect the mains supply using a dedicated User Interface Included in the EST3X basic package, the 4X-LCD provides the user interface for the EST3X system. It connects to the SFS1-CPU main board with a ribbon cable, and attaches to the CPU via hinges. Only one display module is required to provide a point of control for the entire network. Additional displays can be added to any EST3X panel in the network to provide additional points of SpecificationsOperating current Standby Alarm 55mA 66mA LCD display Backlit liquid crystal display 240 x 320 pixels 24 lines of 40 characters Operating environment Temperature Relative humidity 32 to 120 F (0 to 49 C) 0 to 93% noncondensing 3-SDC1 Signature Data Circuit Card SFS1-CPU Main BoardStandard SDC1 card for SLC1Optional SDC1 card for SLC2Each 3-SDC1 Signature Data Circuit Card provides one Class A or Class B signaling line circuit (SLC1) that supports up to 125 Signature Series detectors and 125 Signature Series module addresses. These modules also provide connection for powering conventional two-wire smoke detector circuits on Signature Series comes standard with one 3-SDC1 card installed as SLC1. An optional second 3-SDC1 card may be installed to provide SLC2, thus doubling system signaling line SpecificationsVoltage24 VDCOperating current with fully loaded loop Standby3-SSDC1 144 mA; 3-SDDC1 264 mA Alarm3-SSDC1 204 mA; 3-SDDC1 336 mASmoke VDC B, Class A, or Class XCapacity125 Signature Series detectors and 125 Signature Series modules per SLCResistance100 with 250 F size12 AWG ( mm ) Removable plug-in terminal strips on the SFS1-CPU main board and Signature moduleOperating environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing1For special applications, refer to EST3 ULI/ULC Compatibility Lists (P/N 3100427)SFS1 LED Control/ Display Module Rail ModuleSFS1 LED Control/ Display ModuleThe SFS1 LED Control/Display Module provides additional operator interface capability for the SFS1 system. It can be mounted on any of the three right-most local rail modules on the 3-SFS1 electronics chassis. Inserts are provided for labeling switches and SpecificationsVoltage24 VDCOperating mA plus mA for each active mA plus mA for each active LEDOperating environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensingPage 6 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 3X-FIB fiber optic network module SFS1-CPU Main Board3X-FIB8 adapter cardThe 3X-FIB fiber optic network module gives an EST3X panel the ability to net-work 64 EST3X panels, or interface with an EST3 network. Class A, Class X and Class B connections are supported. The module consists of the adapter card and electronics 3X-FIB supports the following fiber optic transceivers:Model DescriptionSMXLO2Standard output single mode fiber optic transceiverSMXHI2High output single mode fiber optic transceiverMMXVRStandard output multimode fiber optic transceiverThe 3X-FIB provides terminals for connecting a 24 VDC backup power source to maintain data transmissions in the event the panel is powered : All networked panels must have the 3X-FIB network card to VDC (24 VDC nominal)Fiber optics network and audio Budget SMXLO215 dBm between two interfaces SMXHI225 dBm max. and 8 dBm min. 10 dBm between two interfaces MMXVR50/125, , or 100/140 for MMXVRCable typeConnectors50/125, , or 100/140 forSMXLO2, SMXHI2Type Duplex SCMMXVRType STNetwork data circuitCircuit configurationClass B, Class A or Class XData K, kbpsIsolationIsolated from previous panel CPU when using copper. Total isolation when using fiber audio data circuitCircuit configurationClass B, Class A or Class XData rate327 kbpsIsolationIsolated from previous panel CPU when using copper. Total isolation when using fiber wired network data circuit segment CircuitLength5,000 ft. (1,524 m) max. between any three panelsResistance90 F typeTwisted Pair, 18 AWG ( mm ) environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing1Include shield capacitance, if shielding is fiber optic network module SFS1-CPU Main Board3X-FIB adapter cardThe 3X-FIB8 fiber optic network mod-ule gives an EST3X panel the ability to network up to eight EST3X nodes. Class A, Class X and Class B connections are supported. The module consists of the adapter card and electronics 3-FIB8 supports the following fiber optic transceivers:Model DescriptionSMXLO2Standard output single mode fiber optic transceiverSMXHI2High output single mode fiber optic transceiverMMXVRStandard output multimode fiber optic transceiverThe 3X-FIB8 provides terminals for connecting a 24 VDC backup power source to maintain data transmissions in the event the panel is powered : All networked panels must have the 3X-FIB8 network card to VDC (24 VDC nominal)Fiber optics network and audio Budget SMXLO215 dBm between two interfaces SMXHI225 dBm max. and 8 dBm min. 10 dBm between two interfaces MMXVR50/125, , or 100/140 for MMXVRCable typeConnectors50/125, , or 100/140 forSMXLO2, SMXHI2Type Duplex SCMMXVRType STNetwork data circuitCircuit configurationClass B, Class A or Class XData K, kbpsIsolationIsolated from previous panel CPU when using copper. Total isolation when using fiber audio data circuitCircuit configurationClass B, Class A or Class XData rate327 kbpsIsolationIsolated from previous panel CPU when using copper. Total isolation when using fiber wired network data circuit segment CircuitLength5,000 ft. (1,524 m) max. between any three panelsResistance90 F typeTwisted Pair, 18 AWG ( mm ) wired audio data circuit Circuit Length5,000 ft. (1,524 m) max. between any three panels Resistance90 max. F, max1 Wire typeTwisted pair, 18 AWG ( mm ) environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing1Include shield capacitance, if shielding is 7 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 3X-NET8 network card SFS1-CPU Main Board3X-NET8 cardThe 3X-NET8 RS-485 network card gives an SFS1-CPU main board the ability to network through dedicated copper wire up to eight EST3X control panels. The card supports Class B, Class A, or Class X : All networked panels must have a 3X-NET8 network card SpecificationsVoltage24 VDCOperating Current Standby Alarm 98 mA at 24 VDC98 mA at 24 VDCCircuit configurationNetwork dataClass A, Class X, and Class BIsolation Network data Network A port not isolated, Network B port isolatedWire sizeTwisted pair1 18 AWG ( mm) length5,000 ft. (1,524 m) between any three panelsCircuit resistance90 F environmentTemperatureRelative humidity 32 to 120 F (0 to 49 C)0 to 93% noncondensing1 Six twists per foot Network Adapter Card SFS1-CPU Main Board3X-NET cardThe 3X-NET network adapter card gives an SFS1-CPU main board the ability to network up to 64 nodes on an EST3 network. The card supports Class B, Class A, and Class X 3X-NET adapter card provides two independent RS 485 circuits: one for network data communica-tions and one for digital audio SpecificationsVoltage24 VDCOperating CurrentStandby98 mA at 24 VDCAlarm98 mA at 24 VDCCircuit configurationNetwork dataClass A, Class X, or Class BNetwork audioClass A, Class X, or Class BIsolationNetwork dataNetwork A port not isolated; Network B port isolatedNetwork audioAudio A IN and Audio B IN isolatedAudio A OUT and Audio B OUT not isolatedWire sizeTwisted pair1 18 AWG ( mm) length5,000 ft. (1,524 m) between any three panelsCircuit resistance90 capacitanceData: F max.; Audio F environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing1Six twists per foot minimum3X-ETH Ethernet Adapter Cards SFS1-CPU Main Board3X-ETH cardThree optional Ethernet adapter cards are available for EST3X applications. Each of these provide specific features such as panel programming, diagnostics, and status monitoring, as well as central station connectivity, and email or email-to-text messaging communicationsETH1ETH2ETH3CU communications with the Panel for Programming and Diagnostic Functions FireWorks (ECP/IP) Gateway Communications IP Dialer Communications Email and Text Communications Each EST3X control panel supports up to eight IP services, which can provide con-nection to any combination of the following functions: Programming FireWorks Graphical User Interfaces IP Dialer (IP-DACT)EmailEach EST3X network supports up to:10 ECP Connections, and;100 Dialer Accounts, and;100 Email Accounts (up to 20 email addresses per account).3X-ETH1, 3X-ETH2, 3X-ETH3 SpecificationsSee Ordering Information for adapter card functional descriptionsEthernet10/100 Base-TVoltage24 VDCOperating currentStandby42 mA at 24 VDC Active42 mA at 24 VDC Connection modeAuto negotiationWire runsDistance200 ft. (60 m) 5ConnectorRJ-45Operating environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing1Panel to communication equipmentPage 8 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue CLA-PS10 Class A Adapter Card PS10-4B Power supplyCLA-PS10 Class A Adapter CardThe CLA-PS10 Class A Adapter Card is an optional card used to convert the four Class B notification appliance/auxiliary power circuits on the power supply card to Class SpecificationsVoltage24 VDCNotification appliance/Auxiliary power circuitsUL ratingSpecial application or RegulatedQuantity4Performance classClass AOutput currentSpecial A; Regulated: A each circuitEOLR15 k (UL P/N EOL-15, ULC P/N EOL-P1)WiringSupervised, power-limitedWire size18 to 12 AWG ( mm to mm )Operating environmentTemperature32 to 120 F (0 to 49 C)Relative humidity0 to 93% noncondensing3X-PMI Paging Microphone InterfaceThe 3X-PMI Paging Microphone Interface provides controls foremergency voice/alarm communica-tions. It consists of an audio mount-ing bracket, EAEC Emergency Audio Evacuation Controller card, audio enclosure, and paging Paging Microphone Interface SpecificationsVoltageCurrentStandby24 VDC 23mAAlarm29mAGround fault impedance10 k Wire size18 to 12 AWG ( to mm )Audio channels 8 simultaneousAudio inputsLocal microphoneRemote microphoneRemote audioIsolated and supervisedIsolated and supervisedIsolated and supervisedEAEC communicationSee the EAEC Emergency Audio Evacuation Control Installation Sheet (P/N 3101789)MessagesStorageLength2 min. total39 sec. and indicators CommonPaging VolumeReady To Page Paging MicrophoneAll CallAll Call MinusPage To EvacPage To AlertIndicates relative signal strength during active pageFlashes during preannouncement tone, steady when ready to pageActivates/deactivates page to all areasActivates/deactivates page to areas not receiving EVAC or Alert messageActivates/deactivates page to areas currently receiving the EVAC messageActivates/deactivates page to areas currently receiving the Alert messageOperating environmentTemperatureRelative humidity32 to 120 F (0 to 49 C)0 to 93% noncondensingAUDIODATAKEYAUDIOREMOTE MICAUX OUTAUX INNETWORKAUDIOAUDIOAUDIOAUDIOOUTIN+-BBA INA OUTB INB OUT+-+-+-+-ABRS-485+-+-RS-485RX1AA+-TX1T S1ROM1CBUSBUSKEY_OUTAUDIO_OUTSHIELDMN-FV PN SFS1-CPUUL 864 and UL 2572 listed equipment with compatible ratingsRemote microphoneEAECNetwork option card not installedNetwork option card installedMN-PASM2Page 9 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue Ordering Information Intelligent Analog Control PanelsModelDoor ColorLanguageDescription3X-SFS1BBronzeEn glishFACP, complete system with user interface, CPU, one loop with second loop expansion, three option card slots, four Class B NAC, universal 110/220v 10 amp power supply. Order 3-SDC1 for second Flush trim ringNetwork communication option cards3X-NET8RS485, eight node max. Class A, X or B network. Use on 3-SFS systems , eight node max. Class A, X or B network. Use on 3-SFS systems , 8 node max. Uses MMXVR, SMXHI2, SMXLO2. Use on 3-SFS systems motherboard for connection to EST3 systems. Used with MMXVR, SMXHI2 and output single mode fiber optic transceiverSMXHI2High output single mode fiber optic transceiverMMXVRStandard output multimode fiber optic transceiver Communication Options (See 3X-ETH installation sheet P/N 3101794-EN for details on wiring specific applications.)3X-ETH1Ethernet Adapter, 10/100. Provides Ethernet connection from system to 3-SDU for remote programming and diagnostics, and to FireWorks computer graphics workstation. 3X-ETH2Ethernet Adapter, 10/100. Provides the functions of ETH1 plus IP for central station adapter card. Provides the functions of the 3X-ETH2 plus the added capability of sending email messages as well as SMS text messages by means of email-to-text. Front Panel LED/Switch display modules4X-12/S1GYLED Display/Control Module - 12 Switches, 1 Green, 1 YELLOW LED per Display/Control Module - 12 Switches, 1 RED, 1 YELLOW LED per Display/Control Module - 12 Switches with 12 RED Display Module - 12 pairs of LEDs (1 Red; 1 Yellow)4X-24YLED Display Module - 24 YELLOW4X-24RLED Display Module - 24 RED4X-6/3S1G2YLED/Switch Module - six groups of three Switches with one LED Module - six groups of three Switches with one LED Module, four groups of three switches and four LEDs. LED colors: Green, Red, Yellow and Kit, FrenchOption Cards and Interfaces3X-PMIPaging Microphone Interface. See Note Signature Driver Controller, c/w one 3-SDC13-SDDC1Dual Signature Driver Controller, c/w two 3-SDC1s3-SDC1Signature Device Card - expands the 3X base panel to two loops3-SDC1-HC3-SDC1-HC used with circuits that contain more than 90 Watt Zoned Amplifier w/Class A/B Audio & Class A/B 24 VDC outputs3-ZA20B20 Watt Zoned Amplifier w/Class B Audio & Class B 24 VDC outputs3-ZA40A40 Watt Zoned Amplifier w/Class A/B Audio & Class A/B 24 VDC outputs3-ZA40B40 Watt Zoned Amplifier w/Class B Audio & Class B 24 VDC outputs3-MODCOMModem/Dialer (DACT)3-AADC1Addressable Analog Module3-IDC8/4Initiating Device Circuit Module3-LDSMLED Display Support Module. Provides interface for one LED/Switch display module. Mounts in an option card slot where no Option cards are Premises Signaling moduleCLA-PS10Class A Adapter, PS10 NACsCDR-3PSNI Coder ModuleGCIGraphic Annunciator Driver Master, provides outputs for 32 LEDs and connection to common control switches and LEDs for R-Series Annunciator Driver Expander, provides outputs for 48 LEDs and inputs for 24 1: For ULC 11th edition multiple command center applications add MCC to the PMI SKUs as shown, (3X-PMIMCC, 3X-PMIMCC-FR).Page 10 of 10 DATA SHEET E85005-0133 Not to be used for installation purposes. Issue 12-20-17LIFE SAFETY & INCIDENT MANAGEMENTContact : Corporate Park Drive Mebane, NC 27302EDWARDS is a registered mark in the United States and other countries. 2018 United Technologies Corporation. All rights reserved. AccessoriesPS10-4BPower Supply, ReplacementSFS1-ELECBase Electronics, replacement4X-LCDMain user interface assembly, monochrome. Eight line 1/4 VGA LCD, four controls plus rotary knob. English user interface assembly, monochrome. Eight Line 1/4 VGA LCD, four controls plus Rotary knob. Insertable language, shipped with English inserts. Order alternate languages hinged local rail module door4X-CAB6DReplacement door, bronze4X-CAB6DRReplacement door, redCAB6BBackbox, blackCAB6BEQSeismic hardening Kit for batteries up to : For earthquake anchorage, including detailed mounting weights and center of gravity detail, please refer to Seismic Application Guide 3101676-EN. Approval of panel anchorage to site structure may require local AHJ, structural, or civil engineer review.

Related search results